GRP COSHH & Safety Information
This page provides COSHH (Control of Substances Hazardous to Health) and general safety information relating to Glass Reinforced Plastic (GRP) products supplied for riser grating and structural installations.
The information below supports contractors, site managers and health and safety teams during handling, cutting, fabrication and installation.
Material Identification & Use
| Chemical Name | Industrial grating manufactured from fibreglass reinforced polyester resin |
| Common Name | Glass Reinforced Plastic (GRP) / Fibreglass Reinforced Plastic (FRP) |
| Typical Applications | Walkways, Service riser flooring, Trench covers, Platforms, Structural flooring, Stair treads |
Hazard Identification
| Acute Effects | GRP products are not hazardous under normal handling conditions. Dust produced during cutting or grinding may cause skin irritation and itching. Avoid inhalation of dust. |
| Routes of Entry | Skin contact or inhalation of dust generated during cutting or grinding. |
| Medical Note | Individuals with respiratory conditions or sensitivities to dust should avoid cutting or grinding operations. Suitable respiratory protection should be worn. |
First Aid Measures
| Skin Contact | Wash exposed skin thoroughly using soap and water. |
| Eye Contact | Rinse immediately with sterile eye wash solution. Seek medical advice if irritation persists. |
| Inhalation | Remove the operative from the affected area and seek medical advice if symptoms continue. |
Chemical & Physical Data
| Appearance | Solid GRP panels with moulded grid pattern or bonded solid plate surface |
| Standard Colours | Typically RAL 7047 (Grey) or RAL 6010 (Green) |
| Surface Finish | May include applied anti-slip grit |
| Odour | None |
| Solubility | Insoluble in water |
| Specific Gravity | Approximately 1.6 |
Fire Fighting Measures
| Fire Behaviour | GRP products may burn if exposed to sustained direct flame. |
| Extinguishing Media | Water, foam, or A, B or C class extinguishers |
| Combustion Products | Black smoke and carbon particles may be produced |
| Protection | Use appropriate respiratory protection during fire exposure |
| Additional Information | Products are generally self-extinguishing once the ignition source is removed |
Waste Disposal
Dispose of in accordance with local regulations and waste management procedures. GRP products are not classified as hazardous waste.
Handling & Cutting Guidance
- Wear suitable respiratory protection (mask or respirator)
- Wear eye protection
- Cover exposed skin
- Wear gloves when lifting or handling panels
- Use appropriate cutting tools (diamond cutting tools recommended)
Further Information
For additional details regarding installation, chemical resistance, structural loading or compliance documentation, please contact our technical team.
Have a Question?
If you have a question, enquiry or require a bespoke solution, please don’t hesitate to ask.